Welcome to Shenzhen YOURUIAN Technology Co., Ltd.
Sales Hotline 136-8498-6459 admin@youruian.com 中文

一氧化碳 Detection

Formula CO · CAS 630-08-0 · 剧毒 / 易燃 / 窒息

Hazard Level Extreme
Molecular Weight 28.01
Explosive Limits 12.5% ~ 74%
IDLH 1200 ppm

⚠️ Hazards & Toxic Symptoms

Carbon monoxide is a highly toxic gas that is colorless, odorless, and non-irritating (extremely concealed). Its affinity for hemoglobin is 240 times that of O₂, leading to tissue hypoxia. Low concentrations can cause headaches and nausea; exposure to 1500 ppm within one hour can be fatal.

📏 Occupational Exposure Limits (GBZ 2.1-2019)

PC-TWA (Time-Weighted Average)20 mg/m³
PC-STEL (Short-Term Exposure)30 mg/m³
IDLH (Immediately Dangerous to Life or Health)1200 ppm
LEL (Lower Explosive Limit)12.5%
UEL (Upper Explosive Limit)74%

⚠️ Actual alarm thresholds depend on on-site risk assessment. ⚙️ Use the GB Alarm Calculator →

🏭 Typical Application Scenarios

  • Garage / boiler room / gas water heater (domestic)
  • Coke oven/blast furnace gas
  • Vehicle exhaust detection
  • Chemical synthesis
  • Steel/Metallurgy

🔬 Detection Principle / Recommended Sensors

Electrochemical (most common) / Infrared (high-concentration/flue gas analysis)

Common Range:0-500 ppm(环境)/ 0-2000 ppm(工业)

🧪 Try the converter with 一氧化碳 mg/m³ ⇄ ppm bidirectional · auto-applies this gas's MW 28.01

📦 YOURUIAN Recommended Products

Matching product categories: 一氧化碳 detector 一氧化碳 analyzer

Phone Inquiry Products