二硫化碳 Detection
Formula CS₂ · CAS 75-15-0 · 高毒性 / 易燃 / 神经毒性
Hazards & Toxic Symptoms
Carbon disulfide is a colorless, volatile liquid, and its vapor is highly toxic and flammable. It can damage the nervous system (leading to polyneuritis and psychiatric symptoms) and the cardiovascular system. With a low ignition point (90°C), it forms explosive mixtures with air.
Occupational Exposure Limits (GBZ 2.1-2019)
| PC-TWA (Time-Weighted Average) | 5 mg/m³ |
|---|---|
| PC-STEL (Short-Term Exposure) | 10 mg/m³ |
| IDLH (Immediately Dangerous to Life or Health) | 500 ppm |
| LEL (Lower Explosive Limit) | 1.0% |
| UEL (Upper Explosive Limit) | 60% |
⚠️ Actual alarm thresholds depend on on-site risk assessment. ⚙️ Use the GB Alarm Calculator →
Typical Application Scenarios
- Viscose fiber (rayon) factory
- Rubber vulcanization
- Pesticide production
- Chemical synthesis
Detection Principle / Recommended Sensors
Dedicated electrochemical sensor / PID
Common Range:0-100 ppm
📦 YOURUIAN Recommended Products
Matching product categories: 二硫化碳 detector 二硫化碳 analyzer