Online monitoring solution for SF6 gas leakage in power substations
Infrared SF6 online monitoring, coupled with oxygen content monitoring, facilitates a two-tiered alert system - early warning and emergency response

Industry Pain Points
Solution Overview
Yourui'an provides a full lifecycle monitoring solution for substation SF6: ① Fixed SF6 infrared/laser online monitors (accuracy < 0.1 ppm, response < 5 seconds), with 2-4 points per GIS bay; ② Multi-gas combined monitoring of SF6 decomposition products (SO2/HF), for early warning of internal arc faults; ③ Oxygen deficiency alarms (O2 1% linked to power outage for maintenance). The equipment complies with GB/T 8905-2012 + DL/T 596-2021 + Q/CSG 1204001-2014. Optional IoT wireless sensors (without damaging the GIS tank), video linkage (leak point location), and mobile inspection PDA + infrared thermal imaging are available.
## Recommended Locations
– **GIS room**: 1 point each at the top and bottom of each compartment, covering the SF6 deposition area that is heavier than air
– **SF6 gas cylinder storage room**: 6m² with at least one point equipped with O2 monitoring
– **GIS Maintenance Channel**: Portable 4-in-1 Inspection Instrument for SF6, O2, and Decomposition Products
– **SF6 recovery device**: real-time monitoring of flow rate + purity (including micro-water content + oxygen content)
## Key Technical Parameters
– Range: SF6 0-1000 ppm (ambient) / 0-100% Vol (high concentration)
– Accuracy: ≤ ±5% F.S
– Response time: T90 < 30 seconds
– Operating temperature: -25℃ ~ +55℃ (required for outdoor stations)
– Protection level: IP65 (indoor) / IP66 (outdoor)
## Implementation Essentials
1. **Automatic Leak Rate Calculation**: The monitoring platform calculates ppmv/year based on the tank volume and concentration changes, and provides early warning according to the IEC 60376 threshold
2. **Oxygen Deficiency Risk Interlock**: O2 < 19.5% → Emergency Ventilation + Access Control Lockout + SMS Notification to Duty Personnel
3. **Decomposition Product Warning**: Simultaneous increase in SO2 + HF → Early signal of internal arc fault → Immediately check the internal status of GIS
4. **Carbon Emission Disclosure**: Annual data can be directly integrated with GHG Protocol reports, meeting ESG disclosure requirements
## Regulatory Basis
– GB/T 8905-2012 "Guidelines for Management and Detection of Gases in SF6 Electrical Equipment"
– DL/T 596-2021 "Preventive Testing Procedures for Power Equipment"
– Q/CSG 1204001-2014 China Southern Power Grid Enterprise Standard
– GB/T 11023-2018 High-Voltage Switchgear – SF6 Gas Sealing Test
– GB 50016-2014 Code for Fire Protection Design of Buildings (Ventilation Requirements for GIS Rooms)
## Applicable Customers
State Grid / China Southern Power Grid 220kV / 500kV / 1000kV substations, wind power / photovoltaic booster stations, new energy aggregation stations, urban distribution stations, rail transit main transformers, and enterprise-owned substations.
Download the Full Whitepaper PDF
The full version covers technical architecture, sensor selection tables, real engineering cases, deployment timelines, and operational guidance.
Provide your contact info to receive the download.
Recommended Products

Tianyan Series Fixed SF6 Detector

Insight Series Fixed SF6 Detector

Panjue Series Portable Sulfur Hexafluoride Analyzer

Panjue Series Portable Oxygen Analyzer

Pure Crystal Series Online Gas Purity Analyzer/Dew Point Analyzer

PanDun series explosion-proof online hydrogen analyzer
Power industry Industry Case Studies
Real delivery projects in the same industry — useful reference for this solution.
Need a custom solution tailored to your industry?
Contact Us →下载白皮书
请填写联系方式,提交后即可获取下载链接。我们承诺仅用于销售对接,不会公开您的信息。