Product Description: The Y7ID series intelligent gas sensor module is a new generation of gas detection module that supports multiple detection principles such as electrochemical, catalytic combustion, infrared, and thermal conductivity, capable of detecting hundreds of gases. The module converts sensor output signals from various detection principles into standard digital analog signals through high-precision amplification circuit noise reduction, temperature compensation, and high-purity gas calibration. Users can directly use the module to read accurate gas concentration information without dealing with complex and cumbersome issues such as gas detection principles, detection types, and calibration difficulties. The module adopts an intrinsically safe circuit design, with an integrated RS485 driver circuit, and the RS485 output series can directly provide RS485 output. The product features a small size, simple peripheral circuits, and diverse output signals, making it suitable for the detection of toxic and harmful gases, flammable gases, and oxygen concentration. It can be easily integrated into various gas detectors, alarm controllers, industrial process control, and safety monitoring systems.

Application Scenarios

Key Features: High-precision computing circuit, temperature compensation, factory calibration, intrinsically safe circuit design, RS485 direct output, compatibility with multiple detection principles, and superior consistency Product Features: ☆ Utilizes high-precision computing circuitry to ensure measurement accuracy ☆ Supports measurement principles such as electrochemical, catalytic combustion, infrared, and thermal conductivity, capable of detecting hundreds of gases ☆ Equipped with temperature compensation, it has been precisely calibrated at the factory and can be used directly without further calibration ☆ Equipped with a built-in RS485 driver circuit, the Y7ID series can directly provide RS485 output, with EN high-level transmission ☆ Intrinsically safe circuit design, plug and play ☆ Small size, simple peripheral circuitry, and diverse output signals ☆Superior Consistency Product Specifications 1. Performance Gas Detection : Toxic gases, combustible gases, oxygen (Capable of detecting hundreds of gases; please consult for specific gases) Detection Principle: electrochemical, catalytic combustion, infrared, thermal conductivity (selected according to the gas to be detected) Measurement Range: Determined based on the gas being detected; taking CO as an example: 0~50, 500, 1000, 10000 ppm (for other ranges, please consult) Resolution: 0.01, 0.1, 1, 5 ppm (corresponding to the range gear) Accuracy: ±3% Repeatability : ±3% Linearity: ±2% Response time: ≤30s (T90) Zero drift: ±1%F.S/year Signal Output: TTL, RS485, I2C, 0~5V, 0.4~2V Product Lifespan: 2 to 5 years 2. Electrical characteristics Operating Voltage: 5V±1% Operating Current: <40mA (catalytic combustion <90mA) Digital Level: 3.3V (An external level conversion circuit is required when it does not match the host level) Voltage Output: 0~5V or 0.4~2V (other voltages can be customized), output internal resistance <100Ω RS485 Output: The RS485 output series comes with a built-in driver circuit, which can directly provide RS485 signals, with the EN pin sending at high level I2C Pull-up Resistor: A pull-up resistor must be added when using I2C, with a resistance range of 2K~10K Communication Mode: TTL/RS485 is used for passive upload, where the host polls once and the module uploads data once; in I2C mode, the module acts as a slave, with the user's MCU acting as the master 3. Structural characteristics Housing Material : Aluminum alloy Protection Level: IP65 Outline dimensions: φ33.5×31mm (excluding the plug pin) Overall weight: 200g Installation method: Pin-through installation, plug and play 4. Certification and Implementation Standards Intrinsically Safe Design: The intrinsically safe circuit design complies with the requirements of GB3836.4-2010 for the "i" type of intrinsically safe apparatus Design Standards: GB50493-2009 "Design Code for Combustible Gas and Toxic Gas Detection and Alarm in Petrochemical Enterprises"; GB12358-2006 "General Technical Requirements for Environmental Gas Detection and Alarm Instruments in Workplaces" Applicable Standards: GB3836.1-2010 "Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements"; GB3836.4-2010 "Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Intrinsically Safe Type 'i'"; Q/WLA 001-2015 "Enterprise Implementation Standards" Note: For other certifications and third-party testing reports, please consult the manufacturer 5. Operating Environment Operating Temperature: -20~50℃ (Please consult for special requirements) Operating Humidity: 10~95%RH (non-condensing) Operating pressure: 85~105KPa
Phone Inquiry Products