Welcome to Shenzhen YOURUIAN Technology Co., Ltd.
Sales Hotline 135-2848-5810 admin@youruian.com 中文
YBM300 Series

YBM300 Series Pump-Aspirated Gas Sensor Module

Sales Hotline
135-2848-5810
💡 Threshold check / alarm setpoint? Quick links to engineer tools: 🧪 Concentration Converter → ⚙️ GB Alarm Calculator →

Product Overview

Product Description: The YBM300 series pump-aspirated gas sensor module is a new generation of gas detection module specifically designed for a pump-aspirated integrated structure, offering superior gas tightness. The module supports multiple detection principles such as electrochemical, catalytic combustion, infrared, and thermal conductivity, enabling detection of hundreds of gases. It converts sensor output signals from various detection principles through high-precision amplification circuit noise reduction, temperature compensation, and high-purity gas calibration into standard digital analog signals for output. Users can directly use the module to read accurate gas concentration information without dealing with complex and cumbersome issues such as gas detection principles, detection types, and calibration difficulties. The module incorporates an RS485 drive circuit, allowing direct RS485 output; its small size, simple peripheral circuit, and diverse output signals make it suitable for pump-aspirated detection of toxic and harmful gases, flammable gases, and oxygen concentration. It can be easily integrated into various portable/fixed gas detectors, alarm controllers, and online monitoring systems.

Application Scenarios

Key Features: Integrated pump-aspirated design, high-precision computing circuit, temperature compensation, factory calibration, direct RS485 output, compatibility with multiple detection principles, and exceptional consistency   Product Features: ☆ Dedicated to pump-aspirated integrated design, ensuring superior airtightness ☆ Utilizes a high-precision computing circuit to ensure measurement accuracy ☆ Supports measurement principles such as electrochemical, catalytic combustion, infrared, and thermal conductivity, capable of detecting hundreds of gases ☆ Features temperature compensation, precisely calibrated at the factory, ready for immediate use without further calibration ☆ Equipped with a built-in RS485 driver circuit, the YBM300 series can directly provide RS485 output, with EN high-level transmission ☆ Small size, simple peripheral circuit, and diversified output signals ☆Superior consistency Product Specifications 1. Performance Gas Detection : Toxic gases, combustible gases, oxygen (Capable of detecting hundreds of gases; please consult for specific gases) Detection Principle: electrochemical, catalytic combustion, infrared, thermal conductivity (selected according to the gas to be detected) Measurement Range: Determined by the gas being detected; taking CO as an example: 0~50, 500, 1000, 10000 ppm (for other ranges, please consult) Resolution: 0.01, 0.1, 1, 5 ppm (corresponding to the range gear) Accuracy: ±3% Repeatability: ±3% Linearity: ±2% Response time: ≤30s (T90) Zero drift: ±1%F.S/year Signal Output: TTL, RS485, I2C, 0~5V, 0.4~2V Product Lifespan: 2 to 5 years 2. Electrical Characteristics Operating Voltage: 5V±1% Operating Current: <40mA (catalytic combustion <90mA) Digital Level: 3.3V (A level conversion circuit must be added when it does not match the host level) Voltage Output: 0~5V or 0.4~2V (other voltages can be customized), output internal resistance <100Ω RS485 Output: The RS485 output series comes with a built-in driver circuit, which can directly provide RS485 signals, with the EN pin sending at high level I2C pull-up: A pull-up resistor must be added when using I2C, with a resistance range of 2K~10K Communication Mode: TTL/RS485 is a passive upload method, where the host polls once and the module uploads data once; the I2C mode module acts as a slave, with the user's MCU as the master 3. Structural characteristics Housing Material : Aluminum alloy Protection Level: IP65 Outline dimensions: φ40×42mm (excluding probe) Overall weight: 200g Installation method: pump-aspirated integrated installation, direct pin insertion, plug and play 4. Certification and Implementation Standards Intrinsically Safe Design: The intrinsically safe circuit design complies with the requirements of GB3836.4-2010 for the "i" type of intrinsic safety Design Standards: GB50493-2009 "Code for Design of Combustible Gas and Toxic Gas Detection and Alarm in Petrochemical Enterprises"; GB12358-2006 "General Technical Requirements for Environmental Gas Detection and Alarm Instruments in Workplaces" Applicable Standards: GB3836.1-2010 "Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements"; GB3836.4-2010 "Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Intrinsically Safe Type 'i'"; Q/WLA 001-2015 "Enterprise Implementation Standards" Note: For other certifications and third-party testing reports, please consult the manufacturer 5. Operating Environment Operating Temperature: -20~50℃ (Please consult for special requirements) Operating Humidity: 10~95%RH (non-condensing) Operating pressure: 85~105KPa
Phone Inquiry Products